锂电池18650 SPEC
TENTATIVE
4 (8)
LGCRP/BTC Ryu, Duk Hyun
LRB-PS-CY240
2003-07-16 0
LGCRP/BTC Kim, Soo Ryoung
Lithium Ion ICR18650 A3
Initial AC impedance is measured at 1kHz after standard charge.
Initial AC Impedance ≤ 90 m (with PTC)
6.6 Temperature Dependency of Capacity
Cells shall be charged per 6.1 at 23ºC ± 2ºC and discharged per 6.2 at the following temperatures. Relative capacity at each temperature shall meet the following.
Charge Temp.
23ºC
-10 ºC 70 %
Discharge Temperature
0 ºC ºC ºC 90 %
100 %
95 %
6.7 Storage Characteristics
Cells shall be charged per 6.1 and stored in a temperature-controlled environment at 23ºC ± 2ºC for 30 days. After storage, cells shall be discharged per 6.2 to obtain the remaining capacity.
Remaining capacity ≥ 90 % (of minimum capacity in 3.1) 6.8 Cell Voltage (as of shipment)
Voltage range : 3.7 ~ 3.9 V 7.1 Drop Test Test method
Criteria
: Cells charged per 6.1 are dropped onto an wooden floor from 4 feet height for 3 cycles, where each cycle consists of 3 drops, 2 drops from each cell terminal and 1drop from the side of cell can (Total number of drops = 9). After test, cells are discharged per 6.2 and cycled per 6.1 and 6.2 for 3 cycles to obtain recovered capacity.
: No leakage, Capacity recovery rate ≥ 80 %
7.2 Vibration Test
Test method : Cells charged per 6.1 are vibrated for 90 minutes per each of the three mutually
perpendicular axis (x, y, z) with an amplitude of 0.8mm, frequency of 10Hz to 55Hz and sweep of 1Hz change per minute. After test, cells are discharged per 6.2 and cycled per 6.1 and 6.2 for 3 cycles to obtain recovered capacity. : No leakage, Capacity recovery rate ≥ 80 %
Criteria