锂电池18650 SPEC
TENTATIVE
5 (8)
LGCRP/BTC Ryu, Duk Hyun
LRB-PS-CY240
2003-07-16 0
LGCRP/BTC Kim, Soo Ryoung
Lithium Ion ICR18650 A3
8.1 High Temperature Storage Test
Test method : Cells are charged per 6.1 and stored in a temperature-controlled environment at
60ºC for 1 week. After test, cells are discharged per 6.2 and cycled per 6.4 for 3 cycles to obtain recovered capacity.
Criteria : No leakage, Capacity recovery rate ≥ 80 % 8.2 High Temperature and High Humidity Test
Test method : Cells are charged per 6.1 and stored at 60ºC (95% RH) for 168 hours. After test,
cells are discharged per 6.2 and cycled per 6.4 for 3 cycles to obtain recovered capacity.
Criteria : No leakage, No rust, Capacity recovery rate ≥ 80 % 8.3 Thermal Shock Test
Test method : 65ºC (8Hrs) ← 3hrs → -20ºC (8Hrs) for 8 cycles with cells charged per 6.1.
After test, cells are discharged per 6.2 and cycled per 6.4 for 3 cycles to obtain recovered capacity.
Criteria : No leakage, Capacity recovery rate ≥ 80 % 9.1 Abnormal Charge Test
Test method : Cells are discharged per 6.2, then charged at constant current of 7200mA and
constant voltage of 4.2V while tapering the charge current. Charging is continued for 48 hours (Per UL1642).
Criteria : No rupture, No fire 9.2 External Short-circuiting Test
Test method : Cells are charged per 6.1, and the positive and negative terminal is connected by
a 100m -wire for 1 hour (Per UL1642).
Criteria : No rupture, No fire 9.3 Overdischarge Test
Test method : Cells are discharged at constant current of 480mA to 250% of the minimum
capacity (Per UL1642).
Criteria : No rupture, No fire