DIAGNOSTIC UNIT I
Function 01 00 Display of error stack as per: 05.00
显示故障堆栈 Example: Error Explanation 任务特性故障信息 landing 楼层 undefined 未定义 explanations from page 21 解释见21页 Number of marking flag 标志编号 operation phase
Weighting BW
N emergency stop 紧急停梯 S stopping 停止
M spontaneous message 自发信息 B lift blocked 电梯被锁定
Significance: Frequency levels of error:
含义:故障频繁度
Error code number 故障代码
Level 1 infrequent 1度不频繁发生 Level 10 frequent 10度频繁发生
THYSSEN AUFZUGSWERKE
Operating Instructions Diagnostic Unit I Functions
6510Type
046Type No.
Error 01 XX
02 01 02 02
Error description Causes, remedy or instructions BW Interlock contact RK or RKD is jamming in Check interlock contact or mechanical parts of door 6 landing XX. 门锁触点 RK 或 RKD 在 XX 楼层处卡 in landing XX. 住/在 XX 层检查门锁触点或门的机械部件。在任务 A correct door type must be programmed in the job特性程序中必须将门的型号编程输入 specific program. Calls inhibited via monitoring An 8-kbyte RAM is required in CPU. CPU 中需要一块 1召唤因监控作用被禁止 8-KBYTE RAM
Quasi ZSE in lift-specific program released, but Use Thyssen CPU with battery-backed RAM chip Siemens CPU still used. (storage of position in the event of power failure or if 在电梯特性程序中 QUASI 的 ZSE 开关被删掉,但在 HS is switched off). 用 THYSSEN 的 CPU 后备电池的SIEMENS 的 CPU 中仍使用 RAM 芯片(停电或 HS 断开时存储位置信息)
1
02 03 02 04 02 80 03 01
TCM controlTCM 控制
8 k-RAM not recognized; F8 00 will follow8K-RAM 未识别;随之以 F800 TCM 控制
1 1 1 1
TCM control
8 k-EPROM not recognized; F8 00 will follow8KEPRAM 未识别;随之以 F800 未定义或错误的运行阶段
Undefined or wrong operation phase No provision has been madefor disconnect Disconnect landing not programmed (check data landing in lift-specific program. sheet) or incorrect order number on lift-specific 在电梯特性程序中没有编入关梯楼层 EPROM. 关梯楼层未编程(检查数据表)或电梯特性EPROM 中的定单号不正确
03 02 03 03 04 NN
No provision has been made for parking landing Parking landing not programmed, etc., same as for in lift-specific program. error 03 01.在电梯特性程序中没有编入停泊楼层 停泊楼层未编程
No
provision has been made for fireman’s Fireman’s landing not programmed, etc., same as for landing in lift specific program. error 03 01. 消防员在电梯特性程序中没有编入消防员楼层 楼层未编程
TCI: error caused by solenoid switch ZSE.
04 XX
05 YY
05 XX
TCI: CPU checks whether more than one ZSE switch is actuated. If so, the lift will be stopped and error 04 NN stored four times in succession. Check ZSE solenoid switch. TCM: error caused by soldenoid switch ZSE. CPU checks whether more than one ZSE switch is 由磁开关 ZSE 引起的故障/CPU 检查是否有一个以 actuated. All landings XX with ZSE actuated will be 上 ZSE 开关动作,所有 ZSE 动作的楼层 XX 都会显 displayed. Check ZSE solenoid switch, for example 示/检查 ZSE 开关/例如消防员梯 fireman’s lift. Incorrect computer request by group (circuit TCI: Check circuit board MG or group connection board MG defective or fault in group connection). (round cable or flat cable). 来自群控的不正确计算机请求(MG 板损坏或群控 TCM: check group bus (MZ1 circuit board) 接线错误)/TCI:检查 MG 板或群控接线/TCM:检 Software error: identify work program version and 查群控总线(MZ1 板)软件故障:核实工作程序版 subidentification (YY) and inform Thyssen 本和次级标志 YY 并通知蒂森公司 VTS 部 Aufzugswerke department VTS ! Error of TCM lift controls TCM 电梯控制装置的故障 Special program error messages from TCM Inform TU or VTS as soon as this error occurs. group. Will be output after errors indicated XX = Data for detailed error description 一旦发生此故障须通知 TU 或 VTS 部 below !由磁开关 ZSE 引起的故障/CPU 检查是否有一个以 上 ZSE 开关动作,如果是则停梯并故障连续储存 4 次/检查 ZSE 开关/参考来自 21 页的说明 来自 TCM 群控的特殊程序故障信息。在指示出下 XX=故障详细数据 列故障之后会被输出 Number of lifts of group and/or number of 群内电梯数和/或群控楼层数不能接受
SM3
2
-
05 42 05 53 05 A0
-
landings of group unacceptable. Run telegram in incorrect group phase; 05 XX Poor group connection of lift XX XX = lift number XX 电梯的群控接线不良, follows不正确的群控阶段中的运行电报,随之以 XX XX=电梯号
Group protocol incompatible Date ofissue: 07.02
Same program version for all MZ1 circuit boards of Changes: GEGORL Revision
Prepared by: Keinz Issuing Dept.: QMS
D6510-046-B-E.doc
Page: 2
THYSSEN AUFZUGSWERKE
Operating Instructions Diagnostic Unit I Functions
6510Type
046Type No.
05 A8
the group. 群内所有的 MZ1 版本程序相同 Group protocol and group control computer are Check program version of MZ1 circuit board and not compatible group control computer群控协议不兼容 群控协议和群控计算机不兼容 检查 MZ1 板的程序版本和群控计算机
05 b0
Error of TCM with destination selection contro (DC
S)带目的选择控制(DCS)的 TCM 中的 故障 DCS reset, : 05 XX wi …… 此处隐藏:35066字,全部文档内容请下载后查看。喜欢就下载吧 ……