元器件交易网
ADuM1230
PACKAGE CHARACTERISTICS
Table 2.
Parameter
Resistance (Input-to-Output)1Capacitance (Input-to-Output)1Input Capacitance
IC Junction-to-Ambient Thermal Resistance
1
Symbol RI-O CI-O CIθJCaMin Typ Max Unit Test Conditions 1012 2.0 pF f = 1 MHz 4.0 76
The device is considered a 2-terminal device: Pins 1 through 8 are shorted together, and Pins 9 through 16 are shorted together.
REGULATORY INFORMATION
The ADuM1230 is approved, as shown in Table 3. Table 3.
UL1
Recognized under 1577 component recognition program
1
In accordance with UL1577, each ADuM1230 is proof tested by applying an insulation test voltage ≥ 3000 V rms for 1 second (current leakage detection limit = 5 μA).
INSULATION AND SAFETY-RELATED SPECIFICATIONS
Table 4.
Parameter
Rated Dielectric Insulation Voltage Minimum External Air Gap (Clearance) Minimum External Tracking (Creepage)
Minimum Internal Gap (Internal Clearance)
Tracking Resistance (Comparative Tracking Index) Isolation Group
Symbol
L(I01) L(I02) CTI
Value 2500 7.7 min 8.1 min 0.017 min >175 IIIa
Unit V rms mm mm mm V
Conditions
1 minute duration
Measured from input terminals to output terminals, shortest distance through air
Measured from input terminals to output terminals, shortest distance path along body Insulation distance through insulation DIN IEC 112/VDE 0303 Part 1
Material Group (DIN VDE 0110, 1/89, Table 1)
RECOMMENDED OPERATING CONDITIONS
Table 5.
Parameter
Operating Temperature Input Supply Voltage1Output Supply Voltages1
Input Signal Rise and Fall Times
Common-Mode Transient Immunity, Input-to-Output2Common-Mode Transient Immunity, Between Outputs2Transient Immunity, Supply Voltages2
12
Symbol Min Max Unit TA 40 +105 °C VDD14.5 5.5 V VDDA, VDDB12 18 V 1 ms kV/μs kV/μs kV/μs
All voltages are relative to their respective ground.
See the Common-Mode Transient Immunity section for transient diagrams and additional information.
Rev. A | Page 4 of 12