5 结论
(1)采用可见分光光度法快速测定纳米银溶液的浓度是可行的,测定波长为408nm,纳米银溶液浓度在0.2mg/l~10mg/l范围内,测量吸光度值与溶液浓度之间有优异的线性关系(R=0.9998,n=5),相对标准偏差为0.07~0.22%,回收率为98.30~104.44%。 (2)应用于载银抗菌粘胶纤维的制备,可通过测定纳米银溶液浸渍前后的吸光度变化,快速测定载银抗菌粘胶纤维的银含量。 参考文献
[1] 杨东辉. 纳米银溶胶的制备及抗菌性能的研究[J]. 辽宁大学学报,2010,37(4):314-317.
[2] Morones JR, Elechiguerra JL, Camacho A, Holt K, Kouri JB, Ramirez JT, Yacaman MJ. The bactericidal effect of silver nanoparticles [J]. Nanotechnology, 2005, 16: 2346 - 2353.
[3] 胡晓葬,张普柱,孙永华.纳米银抗菌医用敷料银离子吸收和临床应用[J].中华医学杂志,2003,83(24):2178—2179.
[4] Chen X, Schluesener H. Nanosilver: a nanoproduct in medical application [J]. J. Toxicology Letters, 2008, 176: 1 - 12.
[5] Ohashi S, Saku S, Yamamoto K. Antibacterial activity of silver inorganic agent YDA filler [J]. Journal of Oral Rehabilitation, 2004, 31(4): 364 - 367.
[6] Bosetti M, Massè A, Tobin E, Cannas M. Silver coated materials for external fixation devices: in vitro biocompatibility and genotoxicity [J]. Biomaterials, 2002, 23(3): 887 - 892.
[7] 杨娜,严玉蓉,赵耀明. 银系抗菌剂及其在纺织材料中的应用[J]. 化纤与纺织技术,2004,3: 20 - 23. [8] 何秀玲,郭腊梅. 纳米载银无机抗菌剂及其在纺织品上的应用[J]. 上海纺织科技,2003,31(6): 54 - 56.