P4C198/198L, P4C198A/198AL
MAXIMUM RATINGS(1)
VCC
Power Supply Pin withRespect to GNDTerminal Voltage withRespect to GND(up to 7.0V)
Operating Temperature
–0.5 to +7–0.5 toVCC +0.5–55 to +125
V
SymbolTBIASTSTG
V°C
PTIOUT
ParameterTemperature UnderBias
Storage TemperaturePower DissipationDC Output Current
Value–55 to +125–65 to +150
1.050
Unit°C°CWmA
VTERMTA
RECOMMENDED OPERATING
TEMPERATURE AND SUPPLY VOLTAGE
Grade(2)Military
AmbientTemperature
GND0V0V0V
VCC5.0V ± 10%5.0V ± 10%5.0V ± 10%
CAPACITANCES(4)
VCC = 5.0V, TA = 25°C, f = 1.0MHzSymbolCINCOUT
ParameterInput CapacitanceOutput Capacitance
ConditionsTyp.UnitVIN = 0VVOUT = 0V
57
pFpF
–55°C to +125°C0°C to +70°CCommercial
–40°C to +85°CIndustrial
DC ELECTRICAL CHARACTERISTICS
Over recommended operating temperature and supply voltage(2)SymbolVIHVILVHCVLCVCDVOLVOHILIILO ISB
Parameter
Input High VoltageInput Low VoltageCMOS Input High VoltageCMOS Input Low VoltageInput Clamp Diode VoltageOutput Low Voltage(TTL Load)
Output High Voltage(TTL Load)
Input Leakage CurrentOutput Leakage Current
VCC = Min., IIN = –18 mAIOL = +10 mA, VCC = Min.IOL = +8 mA, VCC = Min.IOH = –4 mA, VCC = Min.VCC = Max. Mil.VIN = GND to VCC Ind./Com’l.VCC = Max., CE = VIH, Mil.VOUT = GND to VCC Ind./Com’l.
Test Conditions
P4C198 / 198AP4C198L / 198AL
Unit
MinMaxMinMax2.2VCC +0.52.2VCC +0.5V–0.5(3)–0.5(3)0.5
0.4
2.4–10–5–10–5______
+10+5+10+540352015
2.4–5n/a–5n/a______
+5n/a+5n/a40n/a1.5n/a
0.80.2–1.2
0.5
0.4
–0.5(3)–0.5(3)
0.80.2–1.2
VVVVVVVµAµAmA
VCC –0.2VCC +0.5VCC –0.2VCC +0.5
CE1, CE2 ≥ VIH Mil.
Standby Power Supply
VCC = Max ., Ind./Com’l.
Current (TTL Input Levels)
f = Max., Outputs OpenStandby Power SupplyCurrent
(CMOS Input Levels)
CE1, CE2 ≥ VIH Mil.VCC = Max., Ind./Com’l.f = 0, Outputs OpenVIN ≤ VLC or VIN ≥ VHC
mA
ISB1
n/a = Not Applicable
Notes:
1.Stresses greater than those listed under MAXIMUM RATINGS maycause permanent damage to the device. This is a stress rating onlyand functional operation of the device at these or any other conditionsabove those indicated in the operational sections of this specificationis not implied. Exposure to MAXIMUM ratingconditions for extendedperiods may affect reliability.
2.Extended temperature operation guaranteed with 400 linear feet perminute of air flow.
3.Transient inputs with VIL and IIL not more negative than –3.0V and–100mA, respectively, are permissible for pulse widths up to 20 ns.4.This parameter is sampled and not 100% tested.